{"product_id":"aciq-2-5-ton-30-000-btu-high-efficiency-central-heat-pump-inverter-extreme-series-16-8-seer2-r454b-230v","title":"ACiQ - 2.5 Ton\/30,000 BTU High Efficiency Central Heat Pump Inverter | Extreme Series - 16.8 SEER2 - R454B - 230V","description":"\u003cp\u003eThe ACiQ-30-HPD 2.5 Ton Extreme Series Heat Pump uses inverter technology to adjust compressor speed. It converts AC power to DC, letting the system match BTU output to your needs. This means steady comfort and energy savings as weather changes. The advanced learning condenser tracks temperatures, duct pressure, and refrigerant levels. It learns during startup to optimize future performance for maximum efficiency. With adaptive sizing, this heat pump adjusts to your heating needs. Unlike standard units, it won’t cause excess humidity or discomfort in summer. It runs like a smaller system for ideal cooling and better air quality. Perfect for year-round comfort and lower energy bills.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable BTU output based on demand: 12,000-30,000 BTU for cooling, 12,000-34,000 for heating\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eInverter heat pump system for ducted applications\u003c\/li\u003e\n\u003cli\u003eEfficient cooling from -22°F to 122°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eEfficient heating from -22°F to 75°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eDurable gold fin condenser coil coating for longevity\u003c\/li\u003e\n\u003cli\u003eQuiet operation, even under high workloads\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ctbody data-role=\"additional-info\" data-additional-product-id=\"194578\"\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" scope=\"row\"\u003eACiQ 2.5 Ton 16.8 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SKU\"\u003eACIQ-30-HPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant Charge\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant Charge\"\u003e25'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight (in lbs)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight (in lbs)\"\u003e174.600000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBrand\/Manufacturer\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Brand\/Manufacturer\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eReplaces\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Replaces\"\u003eACIQ-30-HPB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Product Features\"\u003eInverter, Low Ambient Heating, Two Stage Condenser, Variable Speed Condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHSPF2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"HSPF2\"\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCooling BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Cooling BTU\"\u003e30,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeating BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Heating BTU\"\u003e31,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMaximum CFM\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Maximum CFM\"\u003e989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDecibel Level (dBA)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Decibel Level (dBA)\"\u003e60.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectric Heat\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electric Heat\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSEER2 (Efficiency)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SEER2 (Efficiency)\"\u003e16.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCondenser Stages\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Condenser Stages\"\u003eVariable Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCompressor Type\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Compressor Type\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eLiquid Valve Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Liquid Valve Size\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSuction Valve Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Suction Valve Size\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electrical\"\u003e208\/230V 1 Phase 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMax Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Max Breaker Size\"\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin. Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min. Breaker Size\"\u003e29.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eTonnage\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Tonnage\"\u003e2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBTU\/Tonnage\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"BTU\/Tonnage\"\u003e30,000 BTU\/2.5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Heating\"\u003e-22°F - 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Cooling\"\u003e-22°F - 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Ambient Temperature Range\"\u003e-22°F - 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Height\"\u003e31.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Width\"\u003e37.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Depth\"\u003e16.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Warranty\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOwner's Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/HPD-EHPD-Install-Manual_1.pdf?v=1748503540\" target=\"_blank\"\u003eHPD Installation Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/HPD-EHPD-Service-Manual_1.pdf?v=1748503536\" target=\"_blank\"\u003eHPD Service Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825-PDF-1_1.pdf?v=1748503475\" target=\"_blank\"\u003eHPD Heating\/Cooling Performance\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":50715426193730,"sku":"ACIQ-30-HPD","price":2604.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/download_40_4b11372a-78b6-4eda-b051-3b28fe8f38ab.webp?v=1748503569","url":"https:\/\/klondikeac.com\/products\/aciq-2-5-ton-30-000-btu-high-efficiency-central-heat-pump-inverter-extreme-series-16-8-seer2-r454b-230v","provider":"Klondike AC \u0026 Heating","version":"1.0","type":"link"}